The research group "Atomic - mass spectroscopy and analytical chemistry under extreme conditions" of the University of Alicante has developed a method for the diagnosis and prevention of colorectal cancer (CRC). More specifically, an accurate, simple, sensitive and efficient method of extraction and analysis of volatile organic compounds (VOCs) for application as a non-invasive screening test of CRC by stool analysis has been developed.
This method is non-invasive, fast, reliable, economical, highly sensitive and for use in a wide range of patients, so that it can also eliminate or reduce the number of false positives and false negatives.
The technology is developed at laboratory level and is protected by a patent application.
Companies interested in its commercial exploitation are sought.
INTRODUCTION
Colorectal cancer (CRC) is one of the leading causes of cancer death worldwide. Current methods of detecting CRC can be invasive, such as colonoscopies, or non-invasive, such as the faecal occult blood test (FOBT). Although these screening tests have helped to reduce mortality, their performance is not optimal. The FOBT has a substantial number of false negatives and as a consequence a significant number of missed diagnoses of CRC. In addition, a significant percentage of healthy participants who are screened in the population receive a false positive result, which in turn leads to the unnecessary use of colonoscopies. Colonoscopies are an invasive technique, with a risk of complications (bleeding or perforation) as well as a high cost.
Today there are two types of techniques focused on the study of volatile organic compounds (VOCs) for future application in CRC detection; analytical techniques and pattern recognition technologies. Analytical techniques allow the detection of alterations in the presence and concentration of specific molecules, while pattern recognition technologies are non-specific, meaning that they are not selective to a given compound, but to a group of compounds.
There are multiple publications that have provided studies that relate certain biomarkers, some of them VOCs, with the probability of a subject suffering from CRC through different methods. However, none of them have so far provided a method, which is fast, reliable, economical and with high sensitivity, to detect and quantify VOCs that can be useful as biomarkers and at the same time allow the development of a screening method that can reduce or eliminate false positives and false negatives in the detection of CRC.
Therefore, there is a need to develop highly sensitive VOC analysis apparatus and methods that can also quantify VOCs from complex samples such as solid, semi-solid or directly from faeces samples and that are also fast, reliable, sensitive and economical.
TECHNICAL DESCRIPTION
The research group of "Atomic - mass spectroscopy and analytical chemistry under extreme conditions" of the University of Alicante has developed a device adapted for the qualitative and quantitative analysis of volatile organic compounds (VOCs) in solid and/or semi-solid samples, which consists of the following three elements (Figure 1):
The headspace adsorptive magnetic extraction device allows the volatilisation of VOCs from a sample, subjected to a certain temperature. The volatile compounds in the headspace are subsequently retained in an adsorbent trap, which is then desorbed and injected for separation and detection by gas chromatography-mass spectrometry.
This apparatus allows the extraction, identification and quantification of VOCs (P-cresol, 1H-indol, 3(4H)-dibenzofuranone or tetrahydrofolate) from stool samples, known as biomarkers in subjects suffering from CRC, or in subjects who are predisposed to suffering from CRC, to provide a prognosis of the subject's condition or to provide a negative prognosis.
Figure 1. Schematic diagram of the devices used to carry out the analysis, being (1) headspace adsorptive magnetic extraction device; (2) gas chromatograph; (3) mass spectrometer; (4) apparatus for applying temperature and producing magnetic agitation; (5) inert container; (6) solid/semisolid sample; (7) lid; (8) magnet; (9) sorbent supported on the magnet; (10) magnet; (11) glass wool; (12) glass tube.
Therefore, this device can be used as a rapid, effective, selective and non-invasive ex vivo diagnostic method of CRC in a very large number of subjects. To do so, the following steps should be followed:
A typical chromatogram of a subject's ex vivo sample may contain all four of the biomarker compounds cited, in both CRC and healthy control patients.
In summary, this invention has proven to be reliable, sensitive, reproducible, rapid and useful for reducing the number of false negatives or positives, for the diagnosis of colorectal cancer (CRC) in a subject suffering from cancer, or for the predisposition to it, or provides a prognosis of the subject's condition and/or CRC biomarkers or a negative prognosis of such condition.
MAIN ADVANTAGES OF THE TECHNOLOGY
The main advantages of the technology described are as follows:
INNOVATIVE ASPECTS
The main innovative aspect of the technology is the fact that, until now, 3(4H)-dibenzofuranone had not been identified as a possible biomarker related to CRC or as a biomarker in subjects suffering from CRC.
CURRENT STATE OF DEVELOPMENT
The technology is developed at laboratory scale and has been used for the diagnosis of CRC in stool samples.
In this sense, in the analysis carried out, the research group observed that the increase in the concentration of the three biomarkers, 3(4H)-dibenzofuranone, p-cresol or tetrahydrofolate, in a sample of a subject to be evaluated compared with the sample of a healthy subject indicated the presence or the beginning of the disease or the probability of suffering from it or provided a negative prognosis of the subject's condition. Whereas, a decrease in the concentration of the biomarker 1H-indol in a sample of a test subject compared to a sample of a healthy subject indicated the presence or onset of the disease or the probability of having the disease or provided a negative prognosis of the subject's condition.
The method had a very good sensitivity (83% for both p-cresol and 3(4H)-dibenzofuranone) and specificity (80% for p-cresol; and 74% for 3(4H)-dibenzofuranone).
MARKET APPLICATION
The technology described can be used as a method of diagnosis and prevention of CRC. More specifically, this technology is useful to extract and perform accurate, simple, sensitive and effective analysis of VOCs for application as a non-invasive screening test for CRC.
COLLABORATION SOUGHT
Partners sought
Companies interested in acquiring this technology for commercial exploitation through:
Company profile sought:
Ahead of the current Coronavirus outbreak, Innoget is fully committed to contributing to mobilizing scientific and expert communities to find a real solution to the Covid-19 pandemic. Therefore, we're supporting worldwide calls and programs that could help in any aspects of the coronavirus crisis.
Is your organization promoting or looking for innovation or research initiatives to mitigate the Covid-19 outbreak? Email us at covid19@innoget.com to list them.
Channeled through Innoget's online open innovation network, initiatives in the health, virology, medicine, or novel technologies applied to human health, among others, are listed and disseminated to Innoget members -ranging from hospitals, research institutes, scientists, businesses, and public administrations- and innovation partners worldwide.
Create your free account to connect with Javier Montiel Bonmatí and thousands of other innovative organizations and professionals worldwide
Send a request for information
to Javier
Technology Offers on Innoget are directly posted
and managed by its members as well as evaluation of requests for information. Innoget is the trusted open innovation and science network aimed at directly connect industry needs with professionals online.
Need help requesting additional information or have questions regarding this Technology Offer?
Contact Innoget support